mirror of
https://github.com/eclipse-mosquitto/mosquitto.git
synced 2026-05-21 12:24:29 +02:00
Fix signal-args bad behaviour
Closes #3644. Thanks to Gianfranco Costamagna.
This commit is contained in:
parent
5a830e1a78
commit
41246e3f05
|
|
@ -4,10 +4,21 @@
|
|||
|
||||
from mosq_test_helper import *
|
||||
|
||||
def do_test(args, rc_expected, response=None, input=None):
|
||||
proc = subprocess.run([mosq_paths.mosquitto_signal]
|
||||
+ args,
|
||||
capture_output=True, encoding='utf-8', timeout=2, input=input)
|
||||
import os
|
||||
import platform
|
||||
import signal
|
||||
|
||||
def do_test(args, rc_expected, response=None, input=None, sig=None):
|
||||
if sig is not None:
|
||||
signal.signal(sig, signal.SIG_IGN)
|
||||
|
||||
try:
|
||||
proc = subprocess.run([mosq_paths.mosquitto_signal]
|
||||
+ args,
|
||||
capture_output=True, encoding='utf-8', timeout=2, input=input)
|
||||
except KeyboardInterrupt:
|
||||
if sig == signal.SIGINT:
|
||||
pass
|
||||
|
||||
if response is not None:
|
||||
if response not in proc.stderr:
|
||||
|
|
@ -19,18 +30,37 @@ def do_test(args, rc_expected, response=None, input=None):
|
|||
print(proc.returncode)
|
||||
raise ValueError(args)
|
||||
|
||||
if sig is not None:
|
||||
signal.signal(sig, signal.SIG_DFL)
|
||||
|
||||
|
||||
if platform.system() == 'Windows':
|
||||
sighup = None
|
||||
sigint = None
|
||||
sigusr1 = None
|
||||
sigusr2 = None
|
||||
sigrtmin = None
|
||||
else:
|
||||
sighup = signal.SIGHUP
|
||||
sigint = signal.SIGINT
|
||||
sigusr1 = signal.SIGUSR1
|
||||
sigusr2 = signal.SIGUSR2
|
||||
sigrtmin = signal.SIGRTMIN
|
||||
|
||||
pid = os.getpid()
|
||||
|
||||
do_test([], 1) # For the usage message
|
||||
do_test(["--help"], 1)
|
||||
do_test(["--invalid"], 1, response="Error: One of -a or -p must be used.")
|
||||
do_test(["-p"], 1, response="Error: -p argument given but process ID missing.")
|
||||
do_test(["-p", "0"], 1, response="Error: Process ID must be >0.")
|
||||
do_test(["-p", "1"], 1, response="Error: No signal given.")
|
||||
do_test(["-p", str(pid)], 1, response="Error: No signal given.")
|
||||
do_test(["-a"], 1, response="Error: No signal given.")
|
||||
do_test(["-p", "1", "invalid"], 1, response="Error: Unknown signal 'invalid'.")
|
||||
do_test(["-p", "1", "config-reload"], 0)
|
||||
do_test(["-p", "1", "log-rotate"], 0)
|
||||
do_test(["-p", "1", "shutdown"], 0)
|
||||
do_test(["-p", "1", "tree-print"], 0)
|
||||
do_test(["-p", "1", "xtreport"], 0)
|
||||
do_test(["-p", str(pid), "invalid"], 1, response="Error: Unknown signal 'invalid'.")
|
||||
do_test(["-p", str(pid), "config-reload"], 0, sig=sighup)
|
||||
do_test(["-p", str(pid), "log-rotate"], 0, sig=sighup)
|
||||
do_test(["-p", str(pid), "shutdown"], 0, sig=sigint)
|
||||
do_test(["-p", str(pid), "tree-print"], 0, sig=sigusr2)
|
||||
do_test(["-p", str(pid), "xtreport"], 0, sig=sigrtmin)
|
||||
do_test(["-a", "config-reload"], 0)
|
||||
exit(0)
|
||||
|
|
|
|||
Loading…
Reference in a new issue